Ocean Engineering Equipment and Technology››2023,Vol. 10››Issue (2): 8-13.doi:10.12087/oeet.2095-7297.2023.02.02

Previous ArticlesNext Articles

The Hull Structure Design and Practice of the Condensate Storage Tank of Semi-Submersible Platform

LIU Xiaoyan1 , FENGJiaguo2 , LI Da3

  1. 1. CNOOC China Limited , Beijing New Energy Company , Beijing102209 , China ; 2. China National Offshore Oil Corporation, Beijing100010 , China ; 3. CNOOC ResearchInstitute , Ltd . , Beijing100028 , China
  • Online:2023-07-02Published:2023-07-02

Abstract:There is little industrial experience and projects for semi-submersible platform with large volume condensate storage tanks. The hull structure design of condensate storage tanks were provided. Firstly, the column was designed with the double-wall voids (cofferdams ) around the condensate tanks and connected with flats with manholes for maintenance access. Secondly, the pressure head of condensate tank was increased by 10 m compared to the ballast tank after optimizing the reduction of 20 m. Thirdly, the bulkheads of condensate tank are non-watertight and continuous, but with the upper and lower 2 m height gaps for the flowing of condensate and gas. Fourth, the additional corrosion margin of 2 mm was added to the boundary of frequently ballast and de-ballast tanks in the nodes and columns. It is a successful practice for other similar design in the future.

Key words:hull structure,semi-submersible platform,condensate oil storage,strength and fatigue,cofferdam,pressure head.

CLC Number:


Baidu
map